IDEC Supercool 3-Stage
Comprehensive HVAC & MEP Solutions.
How the IDEC 3-Stage Works.

IDEC Supercool – Shaping the Future of Climate Control.
When we design cooling systems, we design them for the long run. The IDEC Supercool 3-Stage is built to transform the way people experience comfort indoors, combining advanced engineering with a deep commitment to sustainability and reliability.
Designed for the Future
Cooling Reimagined
IDEC Supercool 3-Stage Features.
Inside the IDEC: Step-by-Step Journey of Intelligent Cooling
01.
First Stage
02.
Second Stage
03.
Third Stage
04.
Forth Stage
Download the product catalogue
Get detailed specifications and performance insights with our technical datasheet, designed to help you plan with confidence.

Next-Gen Cooling Solutions for a Cleaner, Cooler Tomorrow.
Windmason Arabia’s Extended Product Portfolio

IDEC Supercool 2 Stage
Indirect-direct evaporative cooling (IDEC) system - Two stage adiabatic cooling.

IDEC Supercool 3 Stage
Indirect-direct evaporative cooling (IDEC) system - Three stage adiabatic cooling.

IDEC Supercool 4 Stage
Indirect-direct evaporative cooling (IDEC) system - Four stage adiabatic cooling.











Frequently Asked Questions.
What is the 3-Stage IDEC Cooling System?
The 3-Stage IDEC Cooling System is an advanced evaporative cooling solution designed to work efficiently in humid climates by combining indirect, direct, and condensation-based cooling.
What is the role of the third stage in the 3-Stage IDEC system?
The third stage involves direct evaporative cooling through wet cooling pads, which further cools the air before it is supplied indoors.
How much cooling can the 3-Stage IDEC system achieve?
The system can deliver highly efficient cooling with a supply air temperature as low as 13 °C.
What type of fan is used in the 3-Stage IDEC system?
It features axial top-discharge fans with corrosion-resistant blades, designed for high efficiency and low noise operation.
How does IDEC handle humid weather conditions?
IDEC employs a three-stage cooling process:
- 1st stage: Indirect cooling with a heat exchanger.
- 2nd stage: Further cooling via a chilled water coil.
- 3rd stage: Direct evaporative cooling using wet pads.
What is the expected water consumption of IDEC units?
Water usage is calculated based on 15 hours of daily operation.
Partner with Us for a Healthier, Greener and Sustainable Future.

Get in touch to explore how Windmason can support your next project.
Whether you’re developing a smart city project, upgrading facility cooling, or looking to reduce your carbon footprint—we’re here to help.
📩 Let’s connect and create something impactful.