WINDMASON ARABIA CO.
IDEC Supercool 4 Stage
IDEC (Indirect, Direct, Evaporative Cooling) is a central ducted air conditioning unit that provides energy-efficient cooling without a compressor. Its SUPERCOOL 4-stage evaporative technology reduces electricity consumption by up to 85%, delivering 100% fresh air and lowering temperatures by 7.5°C to 9°C. With advanced filtration and self-cleaning features, IDEC ensures optimal indoor comfort while minimizing environmental impact.
IDEC Supercool 4 Stage
- Multi-stage cooling process ensures optimal temperature control.
- Saves up to 85% electricity by operating without a compressor.
- Equipped with G4 aluminum washable filters, removing up to 99% of dust.
- Equipped with a long-life, direct-drive fan without a belt, suitable for dry air.
- Smart thermostat controller UV Light for disinfecting the air, Lower humidity.
- Offers optimal evaporative cooling performance with wet bulb achievement up to 100%. Includes a heat recovery system for winter ventilation, saving energy.
- Features a touchscreen smart thermostat, auto water drain, and cleaning system.
- Uses reinforced fiberglass layers for wet area protection and durability.
- Designed for commercial, industrial, residential, and governmental projects.
Key Features
Temperature Control
The Smart Temperature Control system features a touchscreen thermostat and inverter technology for efficient cooling, heating, and humidity regulation. It optimizes comfort, energy savings, and fresh air supply automatically.
Energy-Efficiency
The IDEC Supercool ensures energy efficiency by using compressor-free cooling, consuming 85% less electricity, and optimizing temperature control with smart inverters, reducing costs while maintaining optimal indoor comfort.
Whisper-Quiet Operation
The IDEC Supercool system features whisper-quiet operation with axial fans designed for low noise, a direct drive motor, and smooth airflow, ensuring high performance without disturbing indoor environments.
Durability and Reliability
IDEC Supercool is built to last, constructed with high-quality materials and robust engineering. With its durability and reliability, you can trust IDEC Supercool to provide consistent and effective cooling for years to come, making it a wise investment for your comfort needs.
Versatile Applications
Whether you need to cool a small room, a large office space, or a commercial establishment, IDEC Supercool is up to the task. Its versatile design and powerful performance make it suitable for a wide range of applications, ensuring that everyone can benefit from its cooling prowess.
Air Psychosomatic Chart
4-Stage IDEC Cooling at Psychrometric Chart
3d design
Perfectly engineered and designed considering modular approach in 4-Stage IDEC system.
4-Stage of IDEC Supercool
The 1st stage uses an air-to-air heat exchanger to cool incoming air by transferring heat to the outgoing exhaust air without adding moisture. In the 2nd stage, a water-to-air heat exchanger further cools the air through evaporative cooling, adding some moisture. The 3rd stage incorporates a DX evaporator coil, which cools the air further using a refrigerant-based system, similar to air conditioning. Finally, the 4th stage utilizes cooling pads and a secondary fan to enhance cooling efficiency and ensure even air distribution.
Major Components
A direct drive external rotor plug fan with a variable speed inverter. It features an aluminum heavy-gauge impeller, round heavy-gauge brackets. A smooth air inlet cone and the inverter (VFD) provide electrical protection to the motor.
The fans are axial type’s top discharge, protection by a metal mesh fan guard. The blades are coated to prevent corrosion and designed with best air foiling for high performance and low noise. The water-sealed electric motor is directly coupled with the fan, and study round brackets provide support.
A direct drive external rotor plug fan with a variable speed inverter. It features an aluminum heavy-gauge impeller and round heavy-gauge brackets. A smooth air inlet cone and the inverter (VFD) provide electrical protection to the motor.
Equipped with G4 aluminum air filters that are washable, easily accessible, and removable and have a 20mm thick filter media.
The DC inverter receives feedback from the room temperature controller and provides PID functionality to control the room temperature by adjusting the speed of fans. This function not only saves water and power but also ensures smooth indoor comfort.
A heat exchanger is a device that transfers heat between two fluids without mixing them, improving energy efficiency in heating and cooling systems.
Top Industries We Specialized in
Frequently Asked Questions (FAQS)
IDEC (Indirect, Direct, Evaporative Cooling) is an energy-efficient air conditioning system that uses a two-stage or three-stage evaporative cooling process. It cools air without a compressor by first passing outdoor air through a water-cooled heat exchanger (indirect cooling) and then through wet cooling pads (direct cooling), ensuring optimal temperature and humidity levels.
It enhances cooling efficiency by combining different cooling methods to reduce temperature and energy consumption.
It improves airflow distribution, ensuring the cooled air is evenly spread.
Key features include 100% fresh air cooling, self-draining and cleaning technology, G4 washable air filters, 14°C-16°C supply air temperature, and a compressor-free system. Additionally, it offers smart thermostat control, dust reduction, and an optional heating mode.
IDEC eliminates the need for Freon gas and compressors, reducing its carbon footprint and environmental heating effects. It also uses water-based cooling, significantly lowering power consumption and making it an environmentally sustainable solution.
IDEC units use 100% fresh air intake with high-efficiency G4 aluminum washable filters, removing up to 99% of dust and pollen. This ensures clean, healthy, and allergen-free indoor air.
The IDEC-25TR-SUPERCOOL cooling system by Windmason Arabia is a 4-stage evaporative cooling system designed for high efficiency and superior cooling performance. The four stages include:
Indirect Cooling (Air-to-Air Heat Exchanger):
- In this stage, hot incoming air passes through an air-to-air heat exchanger where it loses heat without coming into direct contact with water.
- This process ensures pre-cooling of the air before moving to the next stage.
Indirect Cooling (Water-to-Air Heat Exchanger):
- The air then passes through a water-to-air heat exchanger, where further cooling happens by using chilled water.
- This stage enhances efficiency by removing additional heat before air reaches the direct cooling stage.
Direct Cooling (DX Evaporator Coil):
- The pre-cooled air then passes over a DX (Direct Expansion) evaporator coil, which further reduces the temperature using a refrigeration cycle.
- This stage significantly lowers air temperature and improves humidity control.
Final Direct Cooling (Cooling Pads & Secondary Fan):
- The last stage involves cooling pads, where the air passes through a water-saturated media, further cooling it down through direct evaporative cooling.
- A secondary fan ensures proper airflow and distribution of the cooled air into the space.