Commercial HVAC · Rooftop Package Units

DX Rooftop Package Air Conditioner

When summer temperatures in Saudi Arabia and Middle East push past 45°C, your cooling system has no room for compromise. Windmason Arabia's DX Rooftop Package Air Conditioner Unit (Model: WM-CP-S-300-2-R1) delivers 25 TR of dependable, high-static cooling, factory-rated, pre-charged, and ready to perform from day one.
Built for Saudi Arabia's Extreme Climate

DX Rooftop Package AC Unit

The All-in-One Cooling Solution.

DX Rooftop Package AC Unit combines the condenser and evaporator in one rooftop-mounted body, distributing cooled air through ducts. Windmason WM-CP-S-300-2-R1 offers 25 TR cooling capacity, dual Copeland scroll compressors, and a COP of 10.77 BTU/h/W engineered to operate reliably at 45°C ambient, making it ideal for factories, malls, hotels, and warehouses across KSA.

Why Saudi Facility Managers Choose DX Package AC Units?

A packaged rooftop AC unit solves two problems at once and frees up interior floor space while centralizing the entire refrigeration circuit in a single, weather-resistant enclosure. There’s no refrigerant piping to run between separate indoor and outdoor units, no complex multi-connection commissioning, and no risk of refrigerant leakage through extended pipe runs.

Windmason’s DX Rooftop Package Unit takes this a step further. It ships fully assembled, factory pre-charged with R410A refrigerant, and factory-tested before leaving the facility. After connecting power, duct and thermostat and the system is operational. For project managers working against tight construction timelines across Riyadh, Dammam, or NEOM, that’s a meaningful advantage.

Designed for the Future

Horizontal or vertical airflow configurations accommodate any building layout, from single-story factories to multi-story commercial blocks.

Cooling Reimagined

A COP of 10.77 BTU/h/W with a 70% fan efficiency rating means operating costs stay controlled even through June–September peak cooling months.
Features

Rooftop DX Package AC Features.

Built for long-lasting performance in any climate, the weather-resistant cabinets are made from galvanized steel, and coated with a pre-painted baked enamel finish on all exterior panels. The internal cabinet panels are primed for extended durability and enhanced aesthetics. The unit features a totally enclosed condenser fan motor with permanently lubricated bearings, ensuring greater reliability.
Single point electrical service entry
Side discharge application
Side by side supply and return air
Separate panel for control box
Exceptional endurance tests, Low vibration design
Compressor Protection
Control circuit protected by circuit breaker
Double skin construction, Insulated cabinet
High Efficiency, High Static Blower
Transformer for safe 24v control circuit supply included
Dual, electrically and mechanically independent refrigerant circuit
Thermally protected and permanently lubricated condenser and evaporator fan motors - Angle type return air section with washable type filters
DX Package AC Unit

Download the product catalogue

Get detailed specifications and performance insights with our technical datasheet, designed to help you plan with confidence.

Why This DX Rooftop Package Unit Outperforms in Saudi Conditions.

We stand behind every unit we supply because your facility's comfort depends on equipment that performs reliably, year after year, under some of the world's harshest cooling conditions.

Galvanized Steel, Weather-Resistant

Bonder-ized exterior panels with pre-painted baked enamel finish resist corrosion even in high-humidity coastal cities like Jeddah and Dammam. The internal panels are primed for long-term durability.

Dual Copeland Scroll Compressors

Two independently wired refrigerant circuits with Copeland scroll compressors provide redundancy. If one circuit needs servicing, the other keeps the building cool, a critical feature during peak Saudi summer months.

High-Static Centrifugal Blower

An 18"×18" belt-drive centrifugal blower at 680 RPM delivers 10,000 CFM with 70% fan efficiency across 50mm total static pressure. Single or double-story ducted buildings get the pressure they need.

Rated at 45°C Ambient Factory Proven

Tested at 45°C outdoor ambient with a 26°C indoor setpoint, the actual conditions your rooftop unit will face in Riyadh and interior KSA regions during July and August. No extrapolation required.

Simple Connections with Color-Coded Wiring

Terminal boards in the control box serve the room thermostat, outdoor thermostats, and electric heaters. Power and control wiring, color-coded wires make fault-finding fast during scheduled maintenance.

Non-Corrosive Sloped Condensate Pan

Sloped condensate drainage minimizes biological growth and residual water during off-cycles, directly aligned with Saudi municipality health and safety requirements for commercial food and hospitality spaces.

No Roof Curb Required

Side-by-side supply and return openings with a dedicated base frame allow installation flush against a building face or directly on the rooftop without the cost and complexity of a separate roof curb structure.

R410A / R134A Refrigerant Options

Choose between R410A and R134A refrigerant to match your project's environmental compliance requirements. Both options are supported by Windmason application engineers for optimal system sizing.

Fully Assembled & Pre-Charged

Every unit arrives tested and pre-charged not a flat-pack waiting for a refrigeration engineer. This cuts installation time on-site and reduces commissioning risk on fast-track builds like those across Vision 2030 projects.
Products Visuals

Products Portfolio

Products

top Industries we are specialized in.

We focus on meeting the needs and expectations of our customers, ensuring the highest standards of safety, quality and transparency.
Why Windmason Arabia

Trusted by Commercial Projects Across Saudi Arabia.

Vision 2030 is driving a wave of new commercial construction from Damman, Riyadh, Qaseem to Mecca. Facility owners and M&E contractors need HVAC partners — not just suppliers — who understand both the engineering demands and the local project environment.

Factory-Tested, Field-Ready

Every unit is fully assembled, pressure-tested, and leak-checked before shipment. There's no on-site guesswork, what leaves our facility is what performs on your premises or rooftop.

Saudi-Specific Engineering

Our units are rated and tested at 45°C ambient, not European or North American conditions. When you operate in Riyadh in August, your cooling specifications should reflect that reality.

Direct Technical Support

Reach our engineering and maintenance team directly via phone or WhatsApp for project-specific sizing, duct design consultation, or on-site troubleshooting in both English and Arabic.

Aligned with Vision 2030

Saudi Arabia's National Energy Services Company (TARSHID) and Vision 2030 energy targets demand measurable EER improvements. A COP of 10.77 BTU/h/W positions your facility well within modern Saudi energy benchmarks.

Comprehensive Documentation

Full engineering study, wiring diagrams (power and control circuits), dimensional drawings, and refrigerant cycle diagrams ship with every unit essential for municipality approvals and facility management records.

Durable Engineering

Double-skin insulated cabinet, permanently lubricated bearing motors, and dual independent refrigerant circuits mean lower failure rates and longer service intervals reducing your maintenance costs.
Contact us

Frequently Asked Questions — DX Rooftop Package AC Units

Questions from facility managers, M&E contractors, and procurement teams across Saudi Arabia and Middle East.

Share your project details and we'll provide a tailored air treatment solution with full technical data and lead time confirmation.

Drop us a line! Better yet, see us in person

Contact us for

free consultation

    FAQS

    FAQS.

    What exactly is a DX Rooftop Package Air Conditioner Unit?

    A DX (Direct Expansion) Rooftop Package Unit houses both the evaporator and condenser in one single body, installed on the building rooftop. It cools air through direct refrigerant expansion in the evaporator coil and distributes it through a ducted supply system, unlike split systems that require separate indoor and outdoor units connected by refrigerant lines. The packaged design eliminates long piping runs, reduces installation time, and concentrates all mechanical components in one accessible location.

    Is this rooftop AC unit suitable for Saudi Arabia's 45°C summer heat?

    Yes — and that's a distinction worth emphasizing. Many AC units are performance-rated at 35°C or 40°C ambient, which means their published cooling figures don't reflect real Saudi conditions. The Windmason WM-CP-S-300-2-R1 is specifically tested and rated at 45°C outdoor ambient with a 26°C indoor setpoint. The figures you see in the technical datasheet, 25 TR cooling, 32 kW max power input, represent actual performance in KSA's climate, not laboratory conditions.

    What is the cooling capacity and how large a space can it serve?

    The WM-CP-S-300-2-R1 delivers 25 TR (Tons of Refrigeration) of nominal cooling. As a general reference, 25 TR can cool roughly 700–1,000 m² of well-insulated commercial space, depending on occupancy, solar gain, and activity level. For accurate sizing particularly for factories with high heat loads or glass-fronted retail, we recommend a formal cooling load calculation (حساب الحمل الحراري) before specifying unit quantity. Our team can assist with this.

    Does the DX rooftop unit require a roof curb during installation?

    No. The Windmason unit uses a base frame installation system, it can be positioned close to a building facade or directly on a flat rooftop without the additional cost and structural preparation of a roof curb. Side-by-side supply and return air openings make duct connection straightforward, and the single-point electrical service entry keeps wiring neat and accessible.

    What maintenance does a DX rooftop package unit require in KSA?

    In Saudi Arabia's dusty environment, a routine صيانة (maintenance) schedule should include: cleaning or replacing the 1-inch return air filters every 4–8 weeks during peak season; inspecting the condenser coils for dust and sand accumulation before each summer; checking the non-corrosive condensate pan and drainage; verifying refrigerant charge annually; and lubricating the belt-drive blower assembly. Color-coded wiring and removable service panels make diagnostics fast, reducing downtime during critical cooling months.